Source 1 Product Catalog 2017 Page 96 Air Conditioning & Heating Controls

96 HVAC Components MOTOR PROTECTION SOURCE 1 PART NO. DESCRIPTION MLP $ S1-CC750-115 CC750 COMFORT CONTROL CENTER, 115VAC 636.79 S1-CC750-230 CC750 COMFORT CONTROL CENTER, 230VAC 636.79 S1-PTB47 COIL SENSOR FOR USE W/ CC750 65.54 S1-RSN20 RETURN SENSOR FOR USE W/ CC750 65.54 ICM's award-winning CC750 Comfort Control Center works with your existing air conditioning system or heat pump to improve its effectiveness at air moisture removal, while creating greater system efciencies that help promote energy Ratings: Nominal 24 VAC inputs (25%): 18-30 VAC RMS absolute Operating temperature: -40F to +167F (-40C to +75C) Power consumption: 10 watts typical Line Ratings - Nominal 115 VAC RMS: Inverter operation: 95-135 VAC RMS absolute Bypass operation: 85-145 VAC RMS absolute Maximum inverter amps: 10 amps RMS Maximum bypass amps: 20 amps (60 Hz) Line Ratings - Nominal 208-230 VAC RMS: Inverter operation: 180-264 VAC RMS absolute Bypass operation: 170-264 VAC RMS absolute Maximum inverter amps: 8.5 amps RMS Maximum bypass amps: 10 amps (60 Hz) CC750 Comfort Control Center RELAY SOURCE 1 PART NO. DESCRIPTION MLP $ S1-49P11-843 SURESWITCH RELAY FOR UP TO 40A, 208/240V. 1 OR 1.5 POLE APPLICATIONS 121.18 SureSwitch Relay is a universal electronic upgrade and a superior replacement for mechanical compressor contactors. 5 Reasons to Install SureSwitch relay: 1. Pest Protection: Totally sealed relay to keep out ants and debris; no pest control treatments needed. 2. 5x Life vs. Traditional Contactor: Microprocessor control nearly eliminates contact damage. 3. No Noise: Latching internal relay won't hum or buzz. 4. Time Delays: Protects system when re-starting between regular cycles or after power interruptions. 5. Low Voltage Brownout Protection: Detects and protects system from low voltage events that can cause compressor and fan motors to overheat and fail prematurely. Emerson SureSwitch Relay SOURCE 1 PART NO. COIL VOLTAGE (50/60 HZ) MLP $ S1-S90-290Q 24 11.89 S1-S90-291Q 120 11.86 S1-S90-292Q 240 11.86 *Can be used as an isolation relay for digital thermostats when required. Source 1 Enclosed Fan Relays - 90-290Q thru 90-295q WR/RBM Type 84 Single Pole Single Throw Normally Open (SPST-NO) SOURCE 1 PART NO. COIL VOLTAGE (50/60 HZ) MLP $ S1-S90-293Q 24 12.25 S1-S90-294Q 120 12.25 S1-S90-295Q 240 12.29 *Can be used as an isolation relay for digital thermostats when required. Single Pole Double Throw (SPDT) FAN RELAY

Previous Page
Next Page