95 HVAC Components ICM Freeze Protection Modules FREEZE PROTECTION & DEFROST CONTROLS SOURCE 1 PART NO. TEMPERATURE CUT-OUT (OFF) TEMPERATURE CUT-IN (ON) MLP $ S1-ICM308 43F 45F 30.54 S1-ICM309 28F 55F 30.54 S1-ICM310 44F 48F 30.54 Low-cost, fixed, single setpoint temperature controls that provide freeze protection. Features: Epoxy encapsulated for moisture protection Temperature sensor included Specifications: Input Voltage: 1830 VAC Input Frequency: 5060 Hz Output: Solid state (triac), 1.5A @ 30 VAC Dimensions: 2 x 2 x 1-1/4 ICM Timers & Controls SOURCE 1 PART NO. APPLICATION INPUT VOLT- AGE OUTPUTS MLP $ S1-ICM300 HEAT PUMP DEFROST TIMER 1830 VAC RELAY, SPST, N.O., 1A 49.11 S1-ICM301 HEAT PUMP DEFROST TIMER 1830 VAC RELAY, SPST, N.O., 1A 49.46 S1-ICM302 DEFROST TIMER WITH HIGH POWER FAN RELAY OUTPUT 1830 VAC RATING: 1 AMP @ 30VAC 124.61 S1-ICM303C HEAT PUMP DEFROST CONTROL 1830 VAC 1HP FAN @ 240 VAC; 24 VAC 2A STRIP HEAT/REVERSING VALVE 144.54 S1-ICM304 HEAT PUMP DEFROST TIMER 1830 VAC W: RELAY, SPST, N.O., 10A @ 24 VAC RVS,CC: TRIAC, SPST, N.O., 10A @ 240 VAC FAN: RELAY, SPST, N.O., 10A @ 240 VAC 114.43 S1-ICM307 HEAT PUMP DEFROST TIMER 1830 VAC COMPRESSOR CONTACTS: TRIAC, 1A DEFROST RELAY: TRIAC, 1A 58.89 S1-ICM314 HEAT PUMP DEFROST CONTROL 18-30 VAC TYPE: RELAY, RATING: 1 AMP @ 24VAC 194.11 S1-ICM315 SOLID STATE DEFROST CONTROL 24, 120 OR 240 VAC N.O.: 20A N.C.: 10A @ 240 VAC 194.11 S1-ICM316 SOLID STATE DEFROST TIMER 1830 VAC O, X2: DPST, N.O., 1A @ 30 VAC ODF: SPDT, N.C., 1A @ 230 VAC EDR: PDT, N.C., 1A @ 30 VAC 155.14 S1-ICM317 1830 VAC RELAY, SPST, N.O, 1A 68.89 S1-ICM318 HEAT PUMP DEFROST TIMER 1830 VAC 1/2 HP 240 VAC OUTDOOR FAN RELAY 24 VAC 1A STRIP HEAT RE- VERSING VALVE O, X2: DPST, N.O., 1A @ 30 VAC DF1, DF2: SPST, N.O., 1/2 HP @ 240 VAC 80.14 S1-ICM319 HEAT PUMP DEFROST TIMER 1830 VAC 1/2 HP 240 VAC OUTDOOR FAN RELAY 24 VAC 1A STRIP HEAT REVERSING VALVE O, W2: DPST, N.O., 1A @ 30 VAC RESISTIVE T1, T2: SPST, N.O., 10A @ 24 VAC DF1, DF2: SPST, N.O., 1/2 HP @ 240 VAC 93.18 S1-ICM320 SOLID STATE DEFROST CONTROL 1830 VAC O, W2: DPST, N.O., 2A @ 24 VAC DF1, DF2: SPST, N.O., 10A @ 240 VAC 133.54 S1-ICM321 HEAT PUMP DEFROST TIMER 1830 VAC O, W2: DPST, N.O., 1A @30 VAC RESISTIVE T1, T2: SPST, N.O., 1A @ 30 VAC OF1, OF2: SPST, N.O., 1/2HP @ 240 VAC 119.43 S1-ICM322 HEAT PUMP DEFROST TIMER 1830 VAC O, W2: DPST, N.O., 1A @ 30 VAC T1, T2: SPST, N.O., 1A @ 30 VAC OF1, OF2: SPST, N.O., 1/2 HP @ 240 VAC 105.68 S1-ICM323 HEAT PUMP DEFROST CONTROL 1830 VAC 24 VAC, 1A STRIP HEAT REVERSING VALVES 131.89 S1-ICM330 HEAD PRESSURE CONTROL 1830 VAC MAX: 4 AMPS, MIN: 100mA 353.61 S1-ICM550C-LF DEFROST TIMER 120-240 VAC COMPRESSOR/DEFROST HEATER: RELAY, SPST, N.O., RATING: 40A @ 240 VAC. FAN: RELAY, SPST, N.C., RATING: 30A @ 240 VAC 353.61 Specifications: Input Frequency: 50/60 Hz Power Consumption: 1 watt maximum Output Type: Relay Defrost Time Delay: Fixed 10 minutes 5% Power on Reset Time: 500 milliseconds Test Time: Short across test terminals reduces test time 256x Interval Time Between Defrosts (Pin-Selectable): 30/60/90 Min (Excluding S1-ICM316 and S1-ICM317)

Previous Page
Next Page