83 White Rodgers Snap Disc Fan Controls SNAP DISC LIMIT SWITCHES Electric Heating Controls SPST SOURCE 1 PART NO. FIXED TEMPERATURE SETTINGS SWITCH ACTION "THERM-O-DISC" PART NO. MLP CUT-IN CUT-OUT S1-3L01-120 110 F (43 C) 120 F (49 C) OPEN ON RISE 60T11-610000 14.07 S1-3L01-130 115 F (46 C) 130 F (54 C) OPEN ON RISE 60T11-61002 14.07 S1-3L01-140 100 F (38 C) 140 F (60 C) OPEN ON RISE 60T11-610006 14.07 S1-3L01-150 110 F (43 C) 150 F (66 C) OPEN ON RISE 60T11-610009 14.07 S1-3L01-165 125 F (52 C) 165 F (74 C) OPEN ON RISE 60T11-610069 14.07 S1-3L01-170 130 F (54 C) 170 F (77 C) OPEN ON RISE 60T11-610012 14.07 S1-3L01-180 140 F (60 C) 180 F (82 C) OPEN ON RISE 60T11-610013 14.07 S1-3L01-190 150 F (66 C) 190 F (88 C) OPEN ON RISE 60T11-610015 14.07 S1-3L01-200 160 F (71 C) 200 F (93 C) OPEN ON RISE 60T11-610016 14.07 S1-3L01-230 190 F (88 C) 230 F (110 C) OPEN ON RISE 60T11-610021 13.68 S1-3L01-250 210 F (99 C) 250 F (121 C) OPEN ON RISE 60T11-610023 14.07 S1-3L01-300 250 F (121 C) 300 F (149 C) OPEN ON RISE 60T11-610026 14.07 S1-3L01-350 310 F (154 C) 350 F (177 C) OPEN ON RISE 60T11-610068 14.07 SPECIFICATIONS ELECTRICAL RATINGS MODEL MOTOR RATINGS (FULL LOAD) RESISTIVE (NON-INDUCTIVE) PILOT DUTY 120 VAC 240 VAC 120/240 VAC 277VAC 120/240/277 VAC 3F01, 3F02 10.0 A 5.0A 25.0A 21.6A 125 VA Honeywell R8184G Protectorelay Oil Burner Control Provides automatic, nonrecycling control of an intermittent ignition oil burner system. Approval Bodies: Component recognized by Underwriters Laboratories Inc. Certied by Canadian Standards Association. Approximate Dimensions: 4 in. [108 mm] wide, 4 in. [111 mm] high, 2 in. [64 mm] deep. Ambient Temperature Range: -40 F to 130 F [-40 C to 54 C]. Thermostat Anticipator Setting: 0.2 A. Electrical Ratings: Voltage and Frequency - 120 V, 60 Hz. Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat. Solid state ame sensing circuit. LED on terminal strip indicates system lockout. Remote lockout indication available on some models. External button to manually reset safety switch after lockout. Manual trip lever opens safety switch for system maintenance. Mounts on standard 4 x 4 in. junction box or directly on burner housing. C554A Cadmium Sulde Flame Detector and 24 VAC thermostat required. Load Relay Contacts (A) OIL BURNER PROTECTORELAYS Oil Heating Controls MOTOR RATING 120 VAC 240 VAC FULL LOAD 7.4 3.7 LOCKED ROTOR 44.4 22.2 Ignition Rating - 360 VA (in addition to above motor rating) SOURCE 1 PART NO. SAFETY SWITCH TIMING MLP $ S1-R8184G4009 45 SECONDS 208.29 Limit Controls - Manual Reset SOURCE 1 PART NO. FIXED TEMPERATURE SETTINGS SWITCH ACTION "THERM-O-DISC" PART NO. MLP $ CUT-IN CUT-OUT S1-3L02-160 MANUAL RESET 160 F (71 C) OPEN ON RISE 60T15-330534 23.32 S1-3L02-170 MANUAL RESET 170 F (77 C) OPEN ON RISE 60T15-330535 23.32 S1-3L02-180 MANUAL RESET 180 F (82 C) OPEN ON RISE 60T15-330536 23.32 S1-3L02-190 MANUAL RESET 190 F (88 C) OPEN ON RISE 60T15-330537 23.32 S1-3L02-200 MANUAL RESET 200 F (93 C) OPEN ON RISE 60T15-330538 23.32

Previous Page
Next Page