72 IGNITION MODULES & INTEGRATED FURNACE CONTROLS Gas Heating Controls SOURCE 1 PART NO. DESCRIPTION MLP $ S1-ICM278 LOW COST, FAN BLOWER CONTROL BOARD, CARRIER HH84AA017/18 249.54 ICM278 ICM278 Fan Blower Control - Low cost replacement for Carrier HH84AA017 and HH84AA018 Specications: Input Voltage: Terminals: - 120/240 VAC: N1-N5, S1-S5, H, L, L1, D1 - 18-30 VAC: Y, G, W, C, R, W2, X, HL, PS1, PS2 Line Frequency: 60 Hz Operating Temperature: 40F to +176F Maximum Operating Humidity: 95% R.H.Non-condensing @ 50C Time Delays: - Heat ON: 60 Seconds - Heat OFF: 60-200 Seconds - Cool OFF: 40 Seconds SOURCE 1 PART NO. DESCRIPTION MLP $ S1-ICM284 LOW COST, DIRECT REPLACEMENT FURNANCE CONTROL BOARD 759.93 S1-ICM286 MODULE, CNTRL, FURNACE, GOODMAN 114.93 Features: Controls Vent Motor, Blower Control, Hot Surface Ignitor And Gas Valve Microprocessor Based, Designed For 100% Gas Shutoff In Case Of Ignition Failure Monitors Timing, Trial For Ignition, Flame Sensing And Lockout Diagnostic Leds Aid In Testing/Troubleshooting Specications: Electrical Line Voltage Range: 208 Vac @ 60Hz Ignitor: 5A Resistive @ 208 Vac Cool Blower: 30 A, 2 Hp, 240 Vac Heat Blower: 10 A, 1/2 Hp, 250 Vac Inducer Motor: 4A, 208 Vac Gas Valve: 4A @ 24 Vac Compressor: 5A Resistive @ 24 Vac Environmental Ambient Temperature Operating: -40C To 80C Storage: -40C To 85C Humidity: 5% - 95% R.h. (Non-Condensing) At +55C Replaces: York: S1-03101280000 ICM284 SOURCE 1 PART NO. DESCRIPTION MLP $ S1-ICM288 FURNACE CONTROL BOARD 277.14 Replacement for Rheem 62-24084-82 control boards Specications: Voltage Range: Line 98-132 VAC @ 60Hz Igniter: 5A, 120 VAC Cool Blower: 10A, 2HP, 240 VAC Heat: 5A, 1/2 HP, 250 VAC Inducer Blower: 4A, 120 VAC Gas Valve: 1A, 24 VAC Humidier Motor: 0.5A, 24 VAC Electronic Air Cleaner: 1A, 120 VAC ICM288 SOURCE 1 PART NO. DESCRIPTION MLP $ S1-ICM287 LOW COST, DIRECT REPLACEMENT FURNANCE CONTROL BOARD 253.75 Features: Controls Inducer And Blower Control Microprocessor Based Designed For 100% Gas Shutoff In Case Of Ignition Failure Monitors Timing And Gas Valve Diagnostic Leds Aid In Testing/Troubleshooting Specications: Electrical Line Voltage Range: 120 Vac @ 60Hz Control Voltage: 24 Vac @ 60 Hz Cool Blower: 30 A Resistive @ 120 Vac Heat Blower: 10 A Resisitve @ 120 Vac Inducer Motor: 10A, 208 Vac Gas Valve: 4A Resistive @ 120 Vac Environmental Ambient Temperature Operating: -40C To 80C Storage: -40C To 85C Humidity: 5% - 95% R.h. (Non-Condensing) At +55C Replaces: Goodman: B18099-04 ICM287

Previous Page
Next Page