Source 1 Product Catalog 2017 Page 67 Air Conditioning & Heating Controls

67 Source 1 Silicon Nitride Igniters Source 1's Nitride Hot Surface Igniters provide reliable ignition in a variety of heating systems. Replaces Carrier, Lennox, Rheem, Trane, and others Can reach ignition temperature(s) in 16 seconds 18-gauge nickel chrome lead wires enclosed with high-temperature berglass insulation SOURCE 1 PART NO. DESCRIPTION MLP S1-SCP-700413 IGNITER,HOT SURFACE,ROUND NITRIDE 60.96 S1-SCP-700513 IGNITER,HOT SURFACE,MINI FLAT NITRIDE 56.89 POWER GENERATORS, THERMOCOUPLES, HOT SURFACE IGNITERS, FLAME SENSORS Gas Heating Controls Source 1 Flame Sensors Notes: Sensor rod to be press tted or cemented and must withstand 7 inch-pounds of torque without coming loose. Insulation resistance from rod to bracket must be 500 megaohms minimum Electrode material: Kanthal D, Hoskins 815 or engineering approved equivalent Ceramic material: Alumina 95% or better. Bracket material: Zinc plated (class2, type2 .0003 min. thickness with clear chromate coating) steel or stainless steel Bracket must be tight (withstand 5 in-lb of torque without rotating) Terminal material: Nickel plated steel SOURCE 1 PART NO. DESCRIPTION MLP S1-SCP-9007053 FLAME SENSOR, MODEL 900-3 26.43 S1-SCP-9007054 FLAME SENSOR, MODEL 900-4 26.43 S1-SCP-9007055 FLAME SENSOR, MODEL 900-5 26.43 S1-SCP-9007056 FLAME SENSOR, MODEL 900-6 26.43 IGNITION MODULES & INTEGRATED FURNACE CONTROLS Honeywell S8610U Universal Intermittent Pilot Module Electronic control of most intermittent pilot ignition systems used on gas-red furnaces, boilers and other heating appliances.Provides ignition sequence, ame monitoring and safety shutoff (max. 90 sec.) for intermittent pilot central furnaces and heating appliances. Features 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed. For use with natural or LP gas. For use in single rod or dual rod/remote sense applications. Includes relay contacts for use with any intermittent pilot gas control string with maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended. Functional equivalent of S86, S90, S8600 and S8610 modules. Includes cable adapters to allow eld replacement of both Honeywell and competitive controls without replacing existing cable. Improved enclosure design protects internal circuitry from moisture or dust accumulation. Includes remote reset, and automatic vent damper plug. Replaces most of the following intermittent pilot modules: - Honeywell S86, S90, S8600 and S8610 - Robertshaw SP715, SP715A, SP735, SP735A, SP735L - Johnson GSA, G60, G65, G67, G600, G770 Refer to S8610 specication sheet for a complete list of model numbers. Approval Bodies: - American Gas Association Design certied. - Canadian Gas Association Design certied. Underwriters Laboratories Inc. Component recognized. Ambient temperature rating: -40f to +165f [-40c to +74c]. Flame failure response time: 0.8 Sec. At 1.0 Ma ame current. Wiring connections: 1/4" male quick connect terminals, including ignition terminal (3/16" male quick-connect sense terminal). Electrical ratings: voltage and frequency - 24v (nominal), 60hz. Current rating - 0.2A Note: maximum ambient temperature is 175f [79c] if main valve relay load is 1.0A or less. Thermostat heat anticipator setting: 02a plus pilot valve rating plus main valve rating. Spark generator output - 13 kv peak at 25 pf load. SOURCE 1 PART NO. PILOT MAIN MLP RUNNING INRUSH RUNNING INRUSH S1-S8610U3009 1.0A 10.0A 2.0A 20.0A 306.07

Previous Page
Next Page