Source 1 Product Catalog 2017 Page 62 Air Conditioning & Heating Controls

62 VR8304 Dual Intermittent Pilot Gas Valve Combination gas control for use in 24 VAC, gas-red, intermittent pilot appliances with capacities from 30 to 415 cfh. Features: Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment. Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control Modules. Compact size. Provide two automatic valves. Solenoid operated rst automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. Meet codes requiring dual safety shutoff. Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. All adjustments, wiring connections and pilot outlet are accessible from top of control. Adjustable servo regulator effectively maintains almost constant gas output pressure under wide uctuations in gas supply pressure. Compatible with ECO connector. ON-OFF lighting sequence. Specications: Type: Single Stage Ignition Type: Intermittent Pilot Type of Gas: Natural Body Pattern: Straight-through Opening Characteristics (standard, step): Standard Pressure Ratings (psi): 1/2 psi Pressure Ratings (kPa): 3.5 kPa Pressure Regulator setting (psi): 3.5" W.C. Pressure Regulator setting (kPa): 0.87 kPa Pilot Gas Outlet: Compression tting for 1/4" OD tubing Pressure Tapping: 1/8" NPT with plug Electrical Connections: 1/4" male quick-connects Electrical Ratings: 24 VAC Frequency: 60 Hz Anticipator Setting: 0.7 A Temperature Range (F): -40F to +175F Temperature Range (C): -40C to +79C Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically. Dimensions (in.): 5-3/8"H x 4-1/16"W x 2-11/16"D Dimensions (mm): 135 mm H x 104 mm W x 69 mm D Approvals: American Gas Association IAS AGA Design Certied: File No. L2025007; Canadian Gas Association CGA Design Certied: File No. L2025007; Underwriters Laboratories Inc UL Component Recognized. HONEYWELL GAS VALVES Gas Heating Controls SOURCE 1 PART NO. INLET-OUTLET SIZE CAPACITY @ 1 IN P.D. ACCESSORIES INCLUDED MLP $ S1-VR8304M3509 1/2 IN. x 3/4 IN. 270,000 BTU/HR; 30,000 BTU/HR MINIMUM ONE 3/4 x 1/2 IN. REDUCER BUSHING 393691 NATURAL TO LP GAS CONVERSION KIT 351.83 S1-VR8304M4507 3/4 IN. x 3/4 IN. 300,000 BTU/HR; 30,000 BTU/HR MINIMUM TWO 3/4 x 1/2 IN. REDUCER BUSHING 393691 NATURAL TO LP GAS CONVERSION KIT 342.70 VR8345 Universal Electronic Ignition Combination Gas Control Features: For use with direct spark ignition, hot surface ignition or intermittent pilot ignition in 24 VAC, gas-red appliances, with capacities from 30 to 415 cfh. For use with natural or manufactured gas or LP gas. Includes converter kit to adapt from natural to LP gas. Control includes: manual valve, two automatic operators, pressure regulator (3.5" WC), pilot adjustment, pilot plug and ignition adapter, two 3/4" x 1/2" NPT reducer bushings and one 1/2" x 3/8" NPT bushing. Replaces virtually any IP, HSI or DSI gas control. Clearly marked, keyed terminal block allows quick attachment of wires and IP/DSI/HIS jumper. Internal inlet screen blocks contaminants in gas line from entering valve. Body Pattern: Straight-through with 3/4" x 3/4" inlet and outlet. Dimensions: 5-3/8" H, 4-1/16" W, 2-11/16" D (135 mm H, 104 mm W, 69 mm D) Approvals: AGA Design Certied: File number L2025007; CGA Design Certied: File number L2025007. SOURCE 1 PART NO. IGNITION VOLT OPENING INLET-OUTLET SIZE FUEL MLP S1-VR8345M4302 DIRECT/ INTERMITTENT PILOT 24 STANDARD 3/4 IN. x 3/4 IN. NAT/LP 295.20 Conversion Kits SOURCE 1 PART NO. DESCRIPTION FOR USE WITH MLP S1-391937 NATURAL GAS TO LP CONVERSION KIT, INCLUDING REGULA- TOR SPRING, O-RING, SCREW AND CAP V400 FAMILY, V800 FAMILY, VS820, VS821 STANDARD AND SLOW 26.29 SV9502H2522 System Control The SmartValve System Controls provide easy eld replacement of a wide range of SV9500, SV9501, SV9502 and SV9602 SmartValve System models. Gas appliance manufacturers use these models in many types of gas red heating appliances including central furnaces, residential boilers, rooftop furnaces, commercial cooking appliances, and unit heaters. These controls provide intermittent pilot gas ignition sequencing, pilot ame sensing, and both pilot and main gas control functions in a single control. They are directly compatible with the Q3450 or Q3480 Intermittent Pilot burners used with the original controls on the appliance. Features: Suitable for a wide range of gas-red appliances including residential furnaces, roof-top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking units. Replaces SV9500, SV9501 and SV9502 controls as noted below. Ignition sequence includes timed trial for ignition. SOURCE 1 PART NO. GAS TYPE MLP S1-SV9502H2522 SMART VALVE SYSTEM CONTROL 609.25

Previous Page
Next Page