Source 1 Product Catalog 2017 Page 61 Air Conditioning & Heating Controls

61 VR8204 Intermittent Pilot Dual Automatic Combination Gas Valves Combination gas controls for use in 24 VAC, gas-red intermittent pilot appliances with capacities from 20 to 200 cfh. Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment. Use with S86F,H; S8600F,H and S8610 control modules. Compact size. Provide two automatic valves. Solenoid operated rst automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. Meet codes requiring dual safety shutoff. Natural to LP gas conversion kits are available, but not included. All adjustments and wiring connections are accessible from top of control. VR8204 controls replace the following Honeywell and competitive combination gas controls for applications requiring a minimum capacity of 20 cfh and a maximum capacity of 200 cfh. - Honeywell VR8440 - White Rodgers 36E36/38 - Robertshaw 7100DER (700-070) Approval Bodies: American Gas Association Design certied: File No. L2025006. Canadian Gas Association Design certied: File No. L2025006. Mounting: 0 to 90 from the upright position of gas control knob, including vertically. Body Pattern: Straight-through with 1/2" inlets and outlets. Pressure Tapping: 1/8" NPT with plug. Pressure Rating: 1/2 PSI [3.5 kPa] inlet pressure. Pilot Gas Outlet: Compression tting for 1/4" OD tubing. Ambient Temperature Range: VR8204A,C: 0F to 175F [-18C to +79C]. VR8204M: -40F to +175F [-40C to +79C]. Electrical Data: Supply Voltage: 24 VAC, 60 Hz. Wiring Connections: 1/4" male quick-connects. Thermostat Heat Anticipator Setting: 0.5A. On-Off lighting sequence. SOURCE 1 PART NO. GAS TYPE AMPS @ 24 VAC/60 HZ MAIN PRESSURE REGULATOR SETTING CAPACITY AT 1 IN. P.D. INLET NPTI OUTLET NPTI PIPE IN DIM MLP $ STEP FULL S1-VR8204C1019 NAT 0.5 .9 3.5 150,000 1/2 4.1 377.06 HONEYWELL GAS VALVES Gas Heating Controls VR8205A Direct Ignition Dual Automatic Combination Gas Valves SOURCE 1 PART NO. INLET-OUTLET SIZE CAPACITY @ 1 IN P.D. ACCESSORIES INCLUDED MLP $ S1-VR8300A3500 1/2 IN. x 3/4 IN. 190,000 BTU/HR; 30,000 BTU/HR MINIMUM ONE 3/4 x 1/2 IN. REDUCER BUSHING 393691 NATURAL TO LP GAS CONVERSION KIT 258.45 S1-VR8300A4508 3/4 IN. x 3/4 IN. 200,000 BTU/HR; 30,000 BTU/HR MINIMUM TWO 3/4 x 1/2 IN. REDUCER BUSHING 393691 NATURAL TO LP GAS CONVERSION KIT 277.10 Specications: Type: Single Stage Ignition Type: Standing Pilot Type of Gas: Natural Body Pattern: Straight through with integral tapping; with flange Opening Characteristics (standard, step): Standard Pressure Ratings (psi): 1/2 psi Pressure Ratings (kPa): 3.5 kPa Pressure Regulator setting (psi): 3.5" W.C. Pressure Regulator setting (kPa): 0.87 kPa Pilot Gas Outlet: Compression tting for 1/4" OD tubing Pressure Tapping: 1/8" NPT with plug Electrical Connections: 1/4" male quick-connects Electrical Ratings: 24 VAC Frequency: 60 Hz Anticipator Setting: 0.7 A Temperature Range (F): 0F to 175F Temperature Range (C): -18C to +79C Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically. Dimensions (in.): 5-3/8"H x 4-1/16"W x 2-11/16"D Dimensions (mm): 135 mm H x 104 mm W x 69 mm D Approvals: American Gas Association IAS AGA Design Certied: File No. L2025006; Canadian Gas Association CGA Design Certied: File No. L2025006; Underwriters Laboratories Inc UL Component Recognized. Combination gas control for use in 24 VAC, gas- red, standing pilot appliances with capacities from 30 to 300 cfh. Features: Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment. Compact size. Provides two automatic valves. Solenoid operated rst automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. Meets codes requiring dual safety shutoff. Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. All adjustments, wiring connections and pilot outlet are accessible from top of control. Adjustable servo regulator effectively maintains almost constant gas output pressure under wide uctuations in gas supply pressure. Comatible with ECO connector. LITE-RITE (OFF-PILOT-ON) LIGHTING SEQUENCES.

Previous Page
Next Page