42 Thermostats HONEYWELL DIGITAL THERMOSTATS C7189R Wireless Indoor Temperature Sensor SOURCE 1 PART NO. DESCRIPTION MLP $ S1-C7189R1004 WIRELESS INDOOR TEMPERATURE SENSOR 113.18 Used to sense indoor temperature remotely Features: Used to sense temperature if the thermostat is installed in a poor temperature sensing location. Small remote temperature sensor to match any room decor. Easy to install and use. Factory calibrated; no field calibration required. Works with a maximum 200 foot wire run. 10 K ohm NTC non-linear Temperature Wall Module SOURCE 1 PART NO. DESCRIPTION MLP $ S1-TR21-A SENSOR,TEMPERATURE,AVERAGING,INDOOR RMTE 64.14 Features: Models available with user selectable setpoint adjustment dials in Fahrenheit, Celsius and Relative Scales Models available with occupied/unoccupied override (bypass) with LED Models available with 3-position (auto/0/1) or 5-position (auto/0/1/2/3 speed) fan switch LONWORKS network jack on all models except the TR21 and TR21-A models Models available with on board humidity sensor, humidity output: 0-10Vdc, 0-5 Vdc, 4-20ma selectable For Averaging Only Digital Round Thermostat Provides single-stage temperature control for 24V heating-cooling systems with manual changeover from heat to cool. Features: Attractive styling complements any decor. Large easy-to-read display. Backlit display. On-demand backlighting makes it easy to read the display in a dark room or hallway. No batteries required. Easy installation, set up and 5-minute compressor bypass saves time an dincreases installer productivity. The temperature setting is held permanently in memory in the event of a power failure. Powered through heating-cooling system controls. System and Fan switches, Manual changeover from heat to cool. Easily configurable by the use of DIP switches, F or C temperature display. Selectable heating cycle rates (1, 3, 6, 9 cph) for a variety of applications. Cooling cycle rate is fixed at 3 cph. This is the standard compressor setting for quick installations. Minimum off-time for compressors in the cooling mode. Protects and extends the life of the equipment. Specifications: Mounting: Front wired Changeover: Manual Color: Premier White Power Method: Powered through heatingcooling system controls Switch Type: Electronic Accuracy (F): 0.5C Accuracy (C): 1F Dimensions (in.): 3-11/16 diameter x 1-7/16D Dimensions (mm): 94 mm diameter x 37 mm D Setting Temperature Range (F): 40F to 90F in heating; 45F to 99F in cooling Setting Temperature Range (C): 4.5C to 32C in heating; 7C to 37C in cooling Electrical Ratings: 20 to 30 VAC Cycles per Hour Adj.: 1,3,6,9 Ambient Temperature Range (F): 40F to 110F Ambient Temperature Range (C): 4.5C to 43.3C Humidity Ratings (%RH): 5 to 90% RH Includes Wallplate, 4074FAB resistor, mounting screws and wall anchors SOURCE 1 PART NO. APPLICATIONS STAGES TERMINAL DESIGNATIONS SWITCH POSITIONS MLP $ HEAT COOL FAN SYSTEM S1-T8775C1005 24 VAC GAS, OIL AND ELECTRIC HEATING WITH COOLING,INCLUDING 1 HEAT/1 COOL HEAT PUMPS 1 R, RC, O, B, G, Y, W AUTO-ON OFF-HEAT- COOL 152.50

Previous Page
Next Page