Source 1 Product Catalog 2017 Page 384 Test Instruments and Tools

384 REHVAC NITROGEN PURGING EQUIPMENT Test Instruments SOURCE 1 PART NO. DESCRIPTION MLP $ S1-DT-DP-1 TOOL, NITROGEN PURGE, ADJUSTABLE DIAL 129.89 The Nitrogen Purge Tool is a quick and easy way to purge copper pipes with nitrogen. Then, with a turn of the dial, quickly switch to a very low flow of nitrogen to properly braze the copper. It has a durable aluminum design so you can just throw it into your tool bag when you are done. Purge Flow Rate: 25-35 standard cubic feet per hour 19 - 23 LPM (.03 dia. Orice) Braze Flow Rate: 3-6 standard cubic feet per hour 2-3 LPM (.01 dia. Orice) @ 56-60 psi regulator pressure The purge valve is not a regulator and therefore the output pressure will equal the input pressure when the outlet is blocked. It is not intended to be used with the outlet blocked. The user should not weld a completely closed loop as the pressure will build. We recommend removing the schrader valve and letting it vent. Inlet Pressure for Proper Flow Rates: 50 psi Maximum Pressure: 200 psi Other: male SAE flare are outlet swivel female SAE flare are inlet The thread size is 7/16 - 20 Nitrogen Purge Nitrogen Purge Tool with Adjustable Dial MANOMETERS SOURCE 1 PART NO. DESCRIPTION MLP $ S1-DT-6GPK035 KIT,GAS PRESSURE TEST 154.43 Diversitech Manometers, Pressure Gas Pressure Test Kit