Source 1 Product Catalog 2017 Page 136 Air Conditioning & Heating Controls

136 Zoning, Venting & Economizer Controls ZONING ACCESSORIES & DAMPERS SOURCE 1 PART NO. SIZE (IN.) MLP $ S1-RDM05 5 254.54 S1-RDM06 6 264.75 S1-RDM07 7 266.54 S1-RDM08 8 270.00 S1-RDM09 9 274.04 S1-RDM10 10 277.07 S1-RDM12 12 281.96 S1-RDM14 14 298.61 S1-RDM16 16 312.50 S1-RDM18 18 330.46 S1-RDM20 20 349.75 The S1-RDM can be used for zone control or as the motorized damper for by-pass air when controlled by the Static Pressure Switch, Model S1-SPS. It is designed to also handle high pressure air conditioning systems up to 4S.P. The motor actuator delivers up to 18 in/lbs of torque that powers the S1-RDM open and closed. This powerful motor allows the damper to handle higher static pressures and can be modulates using the SPS Static Pressure Switch or similar type control. Features: 3-wire, power open and close LED damper position indicators Neoprene gasket seal 24 VAC Damper Specications: Construction: 22 Ga. Galvanized Steel Linkage: Direct Drive Motor Voltage: 24 VAC, 50/60 Hz, 6.5 Watts, 7VA Torque: 35 in-lbs. Temperature Rating: -4F to 140F Operating, -20F to 150F Storage Humidity: 5% to 95% Non-Condensing Damper Timing: Nominal 30 Sec. Powered Connection: Screw Terminals Duct Pressure: Maximum 4.0 W.C. Source 1 Modulating Round Zoning Dampers SOURCE 1 PART NO. SIZE MLP $ S1-RRM04 4 241.75 S1-RRM05 5 241.75 S1-RRM06 6 247.00 S1-RRM07 7 247.00 S1-RRM08 8 248.14 A 24 Volt AC, power open, power closed damper. The damper is simply inserted into rigid metal branch ducts. The single blade is powered open and close to control the flow of air to each outlet. The S1-RRM damper blade has a wide wiper seal to seal against the inside of the ducts. The S1-RDM can be used for zone control or as the motorized damper for by-pass air when controlled by the Static Pressure Switch, Model S1-SPS. It is designed to also handle high pressure air conditioning systems up to 4S.P. The simple 3 wire motor has a Red motor release button that allows the damper blade to be manually rotated without harm to the motor. It also has LED position indicators that illuminate GREEN when Open and RED when Closed. The motor actuator delivers up to 18 in/lbs of torque that powers the S1-RRM open and closed. This powerful motor allows the damper to handle higher than normal static pressure, up to 3W.C. Multiple dampers can be wired in parallel. Up to 12 dampers per 40VA transformer. When more than 12 dampers are required use a larger VA transformer. Each motor requires 3VA. Features: Plug-and-play wiring Power open and close LED damper position indicators Rubber gasket seal 24 VAC Temperature Rating: -4F to 140F Operating, -20F to 150F Storage Source 1 Retro-Round Zoning Dampers NOTE: S1-RDM DAMPERS CAN BE USED AS MODULATING POWERED BYPASS DAMPERS WHEN APPLIED WITH S1-SPS STATIC PRESSURE ZONING SWITCH. SOURCE 1 PART NO. DESCRIPTION MLP $ S1-OAS SENSOR,AIR,OUTDOOR 50.50 Senses outdoor air temperature when controlling dual fuel/fossil fuel heat pumps. Source 1 Outside Air Sensor

Previous Page
Next Page