Source 1 Product Catalog 2017 Page 132 Ventilation & Indoor Air Quality

132 Indoor Air Quality SMOKE & GAS DETECTORS SOURCE 1 PART NO. POWER SUPPLY (VOLT) FREQUENCY (HZ) CONTACT RATING OPERATING TEMPERATURE RANGE DIMENSIONS MLP $ S1-C7232A1008 24 VAC (+/- 20%) 50, 60 1 A @ 50 VAC/24 VDC 32F TO 122F (0C TO 50C) 5-1/16"H X 3-11/16"W X 2"D (128 MM H X 80 MM W X 25 MM D) 614.80 S1-C7232A1016 24 VAC (+/- 20%) 50, 60 1 A @ 50 VAC/24 VDC 32F TO 122F (0C TO 50C) 5-1/16"H X 3-5/32"W X 2"D (128 MM H X 80 MM W X 25 MM D) 603.36 S1-C7232B1014 24 VAC (+/- 20%) 50, 60 1 A @ 50 VAC/24 VDC 32F TO 122F (0C TO 50C) 5-5/8" H X 3-5/16" W X 3 7/16" D X plus 8" long sensing tube (142 MM H X 84 MM W X 87 MM D X plus 203 MM sensing tube) 795.54 The Carbon Dioxide (CO2) Sensors and Controllers are stand-alone carbon dioxide (CO2) sensors for use in determining ventilation necessity with HVAC controllers. The sensor measures the CO2 concentration in the ventilated space. (These models are wall-mount only.) The sensors are used in ventilation and air conditioning systems to control the amount of fresh outdoor air supplied to maintain acceptable levels of CO2 in the space. Features: Models available with LCD that provides sensor readings and status information. Non-Dispersion-Infrared (NDIR) technology used to measure carbon dioxide gas. Gold-plated sensor provides long-term calibration stability. C7232 provides voltage or current output based on CO2 levels. Models available with SPST relay output. Proportional plus Integral (P+I) control algorithm. Used for CO2 based ventilation control (Demand Control Ventilation (DCV)). Automatic Background Calibration (ABC) algorithm based on long-term evaluation reduces required typical zero-drift check maintenance. Digital input with programmable delay time for occupancy function using a sensor, pushbutton, or switch. Specications: Mounting: Wall Display: Yes Carbon Dioxide Range: 0 to 3000 ppm Analog Output: 0/2 to 10 Vdc or 0/4 to 20mA w/ one relay output Relay Output: One: Normally Open SPST Accessories: 32002181-001: Zero Calibration Service Accuracy: 5% full scale Timing (response): 2 minutes Honeywell C7232 Carbon Dioxide (CO 2 ) Sensor Zoning, Venting & Economizer Controls CONTROL PANELS SOURCE 1 PART NO. DESCRIPTION ZONES STAGES VOLTAGE MLP $ S1-MZS4 ZONING CONTROL PANEL 4 2H/2C 24 738.57 S1-MZSK ZONING CONTROL PANEL KIT 4 2H/2C 24 824.29 Zone System, Model S1-MZS4 Controls various types of HVAC Equipment all from the same panel. The S1-MZS4 features single stage thermostats to control up to three stage heating and two stages cooling and simple heat pump thermostats to control heat pumps. The S1-MZS4 has various features that make installation and checkout very simple for all of the board's functionality. The S1- MZS4 panel is made of sturdy ABS plastic and can be mounted to any at surface. Wall or return plenum and NOT on the furnace or plenum. The panel can be located in an attic space or in an enclosed cabinet of a rooftop unit. Features Continuous Air Circulation( CAC) in those zones where the thermostat's Fan Switch is set to ON. The S1-MZS4 is factory set for conventional fossil fuel (oil or gas) single and up to three stage heating and two stage cooling. The panel only needs to be con gured when using with an conventional electric furnace or hydro-air system in order to bring the fan on with a call for heat, or when using with a heat pump equipment and thermostats. Features: Color coded push-in wiring blocks LED indicator lights for system operation, Individual zone indicating lights Single stage, two stage, and heat pump compatible Expandable to any number of Zones, Uses any four-wire thermostat Leaving air sensor for capacity protection Staging by time or by number of zones calling, Intelligent changeover timing Source 1 Four-Zone Expandable Control Panels

Previous Page
Next Page