Source 1 Product Catalog 2017 Page 110 Air Conditioning & Heating Controls

110 HVAC Components LINE MONITORS ICM 3-Phase Loss & Reversal Protection Features: Reliable 3-phase protection for single side Monitors for phase reversal, phase loss, unbalance percentage as a function of input voltage Bright LED indicators for On and Fault Highly reliable passive electronics Phase reversal detection on power up Specications: High Voltage Cut-Out Setpoint: +12% Low Voltage Cut-Out Setpoint: -12% Power/Phase Loss Detection: Within 100 ms User Selectable Unbalance Voltage: 2%-8% Voltage: 190-480 VAC Frequency: 50-60 Hz Adjustable Delay on Break: 1-5 min. Relay Output: N.O./N.C. contacts: 10A resistive @ 250 VAC SOURCE 1 PART NO. MOUNT DELAY ON MAKE MLP $ S1-ICM408 8-PIN PLUG-IN 1-5 MIN. 143.14 S1-ICM409 DIN RAIL HEAVY-DUTY SPDT 174.79 ICM 3-Phase Voltage Monitor ICM400 Stop Motor Burnouts! High performance, low cost model, front and back side protection, 7 bright fault LEDs, integral short-cycle protection, easy setup, fully adjustable features, 190- 630 VAC... The ICM400 was specically designed to protect motors and other 3-phase loads from premature failure and damage due to common voltage faults such as voltage unbalance, over/under voltage, phase loss, reversal, incorrect sequencing and rapid short cycling. 3-Position Reset Switch, 50/60 Hz Choose from 3 easy-to-select reset modes: Full manual Full automatic Auto front/manual back Frequency: 50/60 Hz Features: Bright LED's show modes and identify faults: Load energized LED Control voltage LED Lockout LED Front fault LED Back fault LED High voltage LED Low voltage LED Knob-adjustable variables...user may easily select and adjust setpoints on unit: Voltage unbalance: 2-25% Delay on break period: 1-5 min. Fault interrogation: 1-15 sec. Specications: Input Line voltage: universal- 190-630 VAC Frequency: 50/60 Hz Contactor Load Side (Back) Line voltage: universal- 190-630 VAC Load side monitoring is optional. Output Type: relay Voltage range: 240 VAC (max: 10 amps) Control Operating Temperature Operating temperature: -40 to +75C, -40 to 167F Storage temperature: -40 to +85C, -40 to 185F Phase Unbalance Protection Voltage unbalance: 2-25% adjustable Over/Under Voltage Protection Under/over voltage: xed at 12% Hysteresis: 6% Low cost, high performance...full line protection and fault identication without costly LCD readout Integral delay on break timer...knob-adjustable from 1-5 min., helps prevent rapid system recycling Easy to install and congure... wiring diagram on unit, installation and application guide included Phase Loss Protection Phase loss condition = <25% of nominal for any given phase. System will shut down and a fault will be recorded should this condition occur. Delay on Break Timer: Time delay: 1-5 min. adjustable Fault Interrogation Delay Time delay: 1-15 sec. Adjustable Provides a delay between fault detection and system shutdown, eliminating nuisance trips/unnecessary shutdowns. Mechanical Mounting: surface mount using (2) #8 screws Terminations: screw terminals Weight: 12 ounces (341 grams) Dimensions: 6.5" x 4.25" x 1.4" SOURCE 1 PART NO. DESCRIPTION ICM PART NO INPUT OUTPUTS MLP $ LINE VOLTAGE FREQUENCY CONTROL VOLT- AGE S1-ICM400 3-PHASE VOLTAGE MONITOR ICM400 190-600 VAC 50/60 HZ 18-240 VAC/VDC SPDT FREQUENCY: 50/60HZ 311.64

Previous Page
Next Page