Source 1 Product Catalog 2017 Page 107 Air Conditioning & Heating Controls

107 HVAC Components HEAD PRESSURE CONTROLS ICM Head Pressure Controls with Heat Pump Bypass SOURCE 1 PART NO. DESCRIPTION INPUT/OUTPUT VOLTAGE MLP $ S1-ICM325HN ICM HEAD PRESSURE CONTROLS WITH HEAT PUMP BYPASS 120/208/240/480 VAC 238.25 S1-ICM325HNV-LF ICM HEAD PRESSURE CONTROLS WITH HEAT PUMP BYPASS 600 VAC 286.29 S1-ICM326HM2 ICM HEAD PRESSURE CONTROLS WITH HEAT PUMP BYPASS 120 OR 208/240 VAC 356.39 S1-ICM326HN ICM HEAD PRESSURE CONTROLS WITH HEAT PUMP BYPASS 120/208/240 VAC 289.25 S1-ICM327HN ICM HEAD PRESSURE CONTROLS WITH HEAT PUMP BYPASS 480 VAC 314.82 Features: Integral Heat Pump Bypass Circuitry Allows you to electronically bypass the speed control during heat pump operation Solid state 10 amp load carrying capability Single unit controls up to 3 refrigerant circuits Multiple Voltage Ranges Hard Start Adjustable from .1-5 seconds; provides full torque to the motor during startup to help ensure proper fan rotation and lubrication of bearings Low Speed Cutoff Field-adjustable; user may set the minimum RPM level at which the condenser fan should operate High Temperature Bypass Applies full voltage to the condenser fan under normal conditions Integral Transformer *(ICM326HN/327HN models) Simplifies installation, reduces cost; direct setup from the line voltage RoHs Compliant/Lead Free Design For global us Applications Ideal for Low Ambient Conditions Found in: -Supermarkets, frozen food storage -Computer rooms, cooling tower fans -Temperature/humidity-sensitive environment Specifications: Frequency: 50/60 Hz Power Consumption: 4VA @ 24 VAC Output Type: Solid State Form: Triac Output Current: (maximum: 10 amps) (minimum: 100 mA) Frequency: 50/60 Hz Voltage Drop: 3.0 volts maximum Leakage Current: 5 mA maximum Protection Dielectric Breakdown: 2,500 volts maximum Insulation Resistance: 100 M Control Operating Temperature Operating Temperature: -40C to +75C (-40F to +176F) Storage Temperature: -40C to +85C (-40F to +185F) Dimensions ICM325HN: 43/4L X 33/16W X 11/8H ICM326HN and ICM327HN: 43/4L X 33/16W X 13/4H Ordering Information Standard Model ICM325HN: 120-480 VAC Models with Integral Transformers: CM326HN: 120/208/240 VAC ICM327HN: 480 VAC ICM Head Pressure Controls with Temperature & Pressure Inputs and Optional Heat Pump Bypass SOURCE 1 PART NO. DESCRIPTION PROBE CONNECTORS MLP $ S1-ICM333 ICM HEAD PRESSURE CONTROLS WITH TEMPERATURE AND PRESSURE INPUTS AND OPTIONAL HEAT PUMP BYPASS 2 TEMPERATURE PROBES, 2 PRESSURE PROBES 259.43

Previous Page
Next Page